STABILAN-3D The complex is designed for recording, time-tracking, qualitative evaluation, analyzing and simulating human locomotor structures in 3D space simultaneously with the position of center of gravity

SiloKoM-01 portable system for measuring force and moments was designed by the order of the Ministry of Sports, Tourism and Youth Policy of the Russian Federation. The system is intended for immediate control and gradual development and improvement of speed-and-force and force condition of top-level sportsmen based on measuring isometric force moments in ankle, knee and elbow joints. The system also enables evaluating electric activity of muscles using active electrodes.

Hardware and software system for analyzing and correcting powerlifting training techniques using biomechanical and electromyographic parameters. Hardware and software system is intended for recording and analyzing muscle electrical activity, dynamic and kinematic parameters of sportsman movements for training and perfection of bench pressing techniques.

 



(Ask for Price)

 
Enlarge
 

It is a line of professional devices with a great medical potential, reliability in operation, and a capability to display a large amount of information.

The devices are designed for professional application by general practitioners in outpatient departments, ambulance, as well as at home.

The company also produces SCENAR-1-NT-M featurinig information frequency modulations.

The summary table of parameters

"SCENAR-1-NT" version 01

Specifications:

  • influencing impulse frequency is selected in the range from 15 to 350 Hz;
  • “frequency modulation” mode, the range is 30 to 120 Hz;
  • intermittent pulse trains with duration from 1 to 5 sec with the time gap of 1 sec;
  • 4 modes of influencing pulse waveform modification (“damping”);
  • variable pulse waveform (variable damping – var “damping”);
  • “intensive therapy” mode (influencing by impulse packets, the number of impulses in a packet is from 1 to 8);
  • duration of gaps (including variable gaps) between the impulses in each packet can be changed;
  • combined modulation mode (“swing”);
  • several modes of time-dosed high-amplitude influence (a single packet of from 1 to 8 high amplitude impulses) (“like a bee sting” – BEE mode)
  • 2 screening modes; the mode of acupuncture points electroconductivity measuring at alternating current;
  • two algorithms of influence dosing;
  • graphic display of the current reaction dynamics and velocity of its change;
  • a special power decreasing mode for overly sensitive individuals and for treatment of mucous membranes and open wounds;
  • data display on a graphic LCD with backlight;
  • up to 5 different programs can be saved;
  • built-in stop-watch.

"SCENAR-1-NT" version 02
Three modifications of the version are available (see the summary table of parameters)

Specifications:

  • influencing impulse frequency is selected in the range from 15 to 350 Hz;
  • “frequency modulation” mode, the range is 30 to 120 Hz;
  • intermittent pulse trains with duration from 1 to 5 sec with the time gap of 1 sec;
  • 4 modes of influencing pulse waveform modification (“damping”);
  • the mode of variable pulse waveform (variable damping – var);
  • "intensive therapy" mode (influencing by impulse packets, the number of impulses in a packet is from 1 to 8);
  • duration of gaps (including variable gaps) between the impulses in each packet can be changed (“Z” submode);
  • combined modulation mode (“swing”);
  • 1 screening mode;
  • two algorithms of influence dosing;
  • a special power decreasing mode for overly sensitive individuals and for treatment of mucous membranes and open wounds;
  • data display on a graphic LCD with backlight;
  • up to 5 different programs can be saved;
  • built-in stop-watch.

"SCENAR-1-NT" version 03

Specifications:

  • 4 influencing impulse frequencies 15, 60, 120 and 350 Hz;
  • “frequency modulation” mode, the range is 30 to 120 Hz;
  • intermittent pulse trains with duration of 3 sec and the time gap of 1 sec;
  • one algorithm of influence dosing;
  • graphic display of the current reaction dynamics and velocity of its change;
  • data display on a graphic LCD with backlight.

 

Registration cerificate ¹ÔÑ 022à2004/1114-05

Registration cerificate ¹ÔÑ 022à2004/1525-05